GSME
for storage points, extraction + filter systems for the detection of combustion gases.
Plants that are at risk of explosive dust must frequently be provided with explosion protection measures since ignition sources are often unavoidable. In addition to electrostatic phenomena and mechanically generated functions, the most frequent ignition sources particularly include glowing embers, open flames and hot surfaces. Alongside grounding monitoring systems and spark extinguishing systems, the GSME detector series make an enormous contribution to increasing explosion safety. The GSME series have been developed for the early identification of combustion reactions and thermal events, which can ultimately be ignition sources for explosions.
Application
The compact GSME pyrolysis gas detector is specifically tailored for the early detection of hot surfaces and fire in dust-handling equipment, such as silos, dryers, mills, conveyors or dust collectors.
Advantages
- Explosion prevention with early detection of smouldering and developing fires.
- Highest moisture and dust resistance with unique diffusion filter technology.
- Approvals in accordance with ATEX and IECEx.
- Comprehensive explosion safety concepts through the integration of the detectors into the REMBE® EXKOP® Express control unit.
Mechanism
The well-proven multi-criteria technology on a semiconductor base already enables foolproof early detection by the GSME of all types of concealed and open glowing embers and smouldering fires in the emergent phase. The sensor elements of the detectors are protected from dust and moisture with the unique diffusion filter technology. The GSME is also protected from the penetration of moisture and dust due to its robust design. It is specifically designed for use in areas up to Zone 20 and tested in accordance with ATEX and IECEx.
Technical data
Mechanical properties
Housing | Coated die-cast aluminium (corrosion-resistant) |
Dimensions (H x W x D) | 100 x 152 x 100 mm (with cable gland and light module) |
Weight | 0.7 kg |
Protection class | IP 64 |
Detection properties
Sensor combination | CO — H₂ — HC — NOx |
Reaction time | > 30 s |
Detection scenario | Smouldering fires according to EN 54/7, smouldering fires from various organic materials |
Electrical properties
Voltage supply | 20 to 40 V DC |
Power consumption | 10 VA |
Internal fuse protection | 750 mA |
M-Bus Max. line length | ≈ 2 km |
M-Bus Max. line capacity | ≈ 200 nF |
M-Bus Baud rate | 4800 baud |
Limit value contact alarm relay | 680 Ω , 20 mA max. (Alarm closer) |
Limit value contact fault relay | 0 Ω, 40 V or 20 mA max. (Fault opener) |
Thermal properties
Relative humidity | 0 to 99 % relative humidity (non-condensing) |
Temperature | -4 to +122 °F (-20 to +50 °C) |
Applications + Industries
- aerospace
- animal feed productions
- autoclaves
- condensers
- desalination plants
- dual-fuel engines
- elevators
- flare stacks
- food
- LNG
- mills and grinding plants
- reactors
- reverse osmosis systems
- separators
- silo
- water injection pumps
Certifications
ATEX
IECEx
Downloads
In contrast to conventional fire detection systems, the selection and positioning of special fire detectors is a particular challenge for industrial environments. The arrangement and alignment of the detectors should therefore be exclusively specified by specialist planners.
Click and drag image to view.
The dimensions shown may differ from those of the actual product.
* Requires iOS 13, iPadOS 13, ARCore 1.9 or higher.
* Requires iOS 13, iPadOS 13, ARCore 1.9 or higher.
Any Questions?
We would be happy to show you solutions tailored to your process that limit the effects of an explosion to a harmless level and ensure that production can be resumed quickly after an explosion event.